Brier Park Gravity Bypass

Brier Park Auger Bore

Medicine Hat, Alberta

This project incorporated the combination of larger diameter Auger Bore methods with the use of a Sanitary Sewer Bypass System. Auger Bore drill shots were highly monitored in regards to above rail line settlement. Sewer bypassing occurred in a residential regions therefore, noise cancellation techniques were utilized to silence the Sanitary Sewer Bypass generator allowing residents to be undisturbed. Specific scopes of work included:

  • 72 meter Auger Bore beneath a CP Railway involving a 1500mm steel casing for a Sanitary Sewer line
  • 72 meter Auger Bore beneath Altawanna roadway involving a 1500mm steel casing for a Sanitary Sewer line
  • 29 meter Auger Bore beneath Parkview roadway involving a 1500mm steel casing for a Sanitary Sewer line